Icynene’s gap-free foam virtually eliminates the need for any detailed special air seal or air barrier treatment such as building wraps (subject to local building codes). A consistent, comfortable temperature is maintained inside, and the cold is kept outside.
Due to its on-site, custom application and air sealing ability, The Icynene Insulation System® allows for greater freedom in project design. Quality control problems during construction are a thing of the past, since foam is custom-applied to every building. Icynene® simplifies detailing and construction methods, while delivering superior performance. Icynene® eliminates cold corners, walls and floors over unheated spaces and delivers better overall comfort and even temperatures throughout the building.
Icynene® meets the Specific Challenges of Cold Weather Construction:
- Can be installed in any climate condition down to -22o F (-30o C) without the need to preheat the building
- Eliminates the need for double walls or double floors
- Reduces construction time, labor and material costs
- Ideal for multi-unit buildings (offices, hotels, apartments, etc.) due to energy efficiency and sound barrier properties
- Permits innovative designs such as cathedral ceilings, perimeter joist spaces, crawl spaces, wine cellars, humidors and flat roofs
- Maintains original cured form - does not shrink, settle or sag
Below is a summary of the product specification. Please ask for full product specifications before using.
| Environmental Characteristics | |
|---|---|
| • CFCs or HCFCs | none |
| • Formaldehyde | none |
| • Corrosiveness | negative |
| • VOCs after 30 days | none detectable |
| Flammability Characteristics | |
| • Flame spread ASTM E84 | <20 |
| • Smoke developed | <400 |
| • Fuel contribution | zero |
| • Oxygen index | 23 |
| Physical Properties | |
| • Density | 0.5 lb/cf |
| • Thermal Resistance | R-3.6/in |
| Heat flow reduction through 1” | 72.7% |
| Heat flow reduction through 3.5” | 92.2% |
| Heat flow reduction through 5.5” | 95.0% |
| Heat flow reduction through 10” | 97.3% |
| • Vapor permeance - 5” | 10 perms |
| • Sound transmission class | 37 |
| • Noise reduction coefficient | 70 |
| Evaluations and Approvals | |
| B.O.C.A., I.C.B.O., S.B.C.C.I., N.E.S., C.C.M.C. | |